ANALISIS SIFAT FISIK DAN DAYA DUKUNG TANAH (Studi Kasus: Jl. Lolong Karan, Sungai Sapih, Kec. Kuranji, kota Padang)

Authors

  • Firnandi Firnandi Departemen Teknik Sipil FT UNP
  • Fithriyah Patriotika Departemen Teknik Sipil FT UNP

DOI:

https://doi.org/10.24036/gfrj6g08

Keywords:

Bearing Capacity, Dynamic Cone Penetrometer (DCP), California Bearing Ratio (CBR), Soil Physical properties.

Abstract

The study is motivated by the occurance of pavement damage in the form of surface deformation, which is presumed to be caused by thre low bearing capacity of the subgrade. the study aims to analyze the physical properties and bearing capacity of soil on jalan Lolong Karan, Sungai Sapih, Kecamatan Kuranji, Kota Padang. The research methods include laboratory testing of soil physical properties, such as water content, specify gravity, Atterberg limits, sieve analysis, and hydrometer analysis, as well as field testing using the Dynamic Cone Penetrometer (DCP) to obtain the California Bearing Ratio (CBR) value. The results show that the soil at the study location is predominantly sandy soil containing silt, with characteristics that influence the soil bearing capacity. THE CBR values obtained from DCP testing are mostly below the minimum standard, indicating that the subgrade as low bearing capacity and is less stable in supporting traffic loads. The main factors influencing this condition are high water content and the surrounding environment, which stabilization are required to increase the soil bearing capacity 

References

Afrida, M. F. D., & Senja Rum Harnaeni. (2022). Analisa Nilai Kepadatan Tanah Dasar (Subgrade) Dengan Pengujian Dynamic Cone Penetrometer (Dcp) Pekerjaan Akses Jalan Bandara Internasional Dhoho Kediri. Jurnal Prosiding Universitas Muhammadiyah Surakarta, 367–374.

Amran, Y., & Surandono, A. (2017). Analisa Daya Dukung Tanah (Ddt) Pada Sub Grade/Tanah Dasar (Studi Kasus Ruas Jalan Ki Hajar Dewantara, 38 B Banjar Rejo Lampung Timur-Batas Kota Metro). Tapak (Teknologi Aplikasi Konstruksi), 7(1), 1–6.

Badan Standardisasi Nasional. (1990). Metode Pengujian Batas Cair tanah dengan alat Cassagrande (SNI 03-1964-1990). Jakarta: Badan Standardisasi Nasional.

Badan Standardisasi Nasional. (1990). Metode Pengujian Batas Plastis dan Indeks Plastistas Tanah (SNI 03-1965-1990). Jakarta: Badan Standardisasi Nasional.

Badan Standardisasi Nasional. (2008). Cara Uji Analisis Ukuran Butiran Tanah (SNI 3423:2008). Jakarta: Badan Standardisasi Nasional.

Badan Standardisasi Nasional. (2019). Metode Uji Penentuan Kadar Air Untuk Tanah dan Batuan Di Laboratorium (SNI 1965:2019). Jakarta: Badan Standardisasi Nasional.

Das, B. M. (1995). Mekanika Tanah Jilid 1(Prinsip-Prinsip Rekayasa Geoteknik). In Penerbit Erlangga.

Hardiyatmo, H. C. (2008). Mekanika Tanah I. Gadjah Mada University Press, 1.

Kementerian Pekerjaan Umum (2010). Surat Edaran Menteri Pekerjaan Umum No . 04 / Se / M / 2010 Tentang Pemberlakukan Pedoman Cara Uji California Bearing Ratio ( Cbr ) Dengan Dynamic Cone Penetrometer ( Dcp ) Kementerian Pekerjaan Umum. Pemberlakukan Pedoman Cara Uji California Bearing Ratio (Cbr) Dengan Dynamic Cone Penetrometer (Dcp), 1(04), 1–20.

Metboki, M. (2024). Pengujian Berdasarkan Sni Untuk Mengetahui Sifat Fisik Dan Mekanis Tanah. Ahsana: Jurnal Penelitian Dan Pengabdian Kepada Masyarakat, 2(2), 40–43.

Trisnawati, L., & Erny. (2024). Pengujian Daya Dukung Lapis Tanah Dasar (Subgrade) Menggunakan Alat Dcp (Dynamic Cone Penetrometer) (Studi Kasus: Jl. Pendidikan Desa Rantau Mapesai Kecamatan Rengat Kabupaten Indragiri Hulu). Innovative: Journal Of Social Science Research, 4, 259–271.

Downloads

Published

2026-05-04

How to Cite

ANALISIS SIFAT FISIK DAN DAYA DUKUNG TANAH (Studi Kasus: Jl. Lolong Karan, Sungai Sapih, Kec. Kuranji, kota Padang). (2026). Jurnal Applied Science in Civil Engineering, 7(2), 84-91. https://doi.org/10.24036/gfrj6g08